{"product_id":"k-rain-6404-rcw-6000-rcw-indexing-valve-4-outlet-4-zone-operation","title":"K-Rain - 6404-RCW - 6000 RCW Indexing Valve: 4 Outlet 4 Zone Operation","description":"\u003cp\u003eThe 6000 line of indexing valves offers exceptional reliability and durability even under the dirtiest water conditions. With a metal die-cast body, the 6000 valves are capable of high-pressure applications and are recommended to be used on pump fed systems or high-flow city water systems. The 6000 is also ideal for onsite wastewater and effluent water applications.\u003c\/p\u003e\n\u003cp\u003eWith only one moving part (the stem and disc assembly), the valve is easily serviced and maintained. The valve requires 15 GPM (57 LPM) to operate and works at pressures from 25 to 150 PSI (1,7 to 10,3 bar).\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFour Outlet: 1 1\/2\" Threaded Inlet x 1 1\/2\" Slip Outlets\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCam for 4 Zone Operation Only\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePurple Cap for Reclaimed Water Use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e: 15 - 150 GPM (57-568 LPM)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e: 25 - 150 PSI (1.7 to 10.3 bar)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInlet\u003c\/strong\u003e: Threaded NPT Connection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e: Slip and Glue Connections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePressure Loss\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFLOW (GPM)  20   40   60   80  100\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePSI LOSS        2.5  3.5   5.0  7.5 10.0\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eThis Model has a Cam for 4 Zone Operation Only\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0167\/3543\/6900\/files\/IndexingValveActiveZoneDiagram.jpg?v=1676990294\u0026amp;width=700\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFEATURES AND BENEFITS\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMetal Die-Cast Body\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e– Durable, long lasting and capable of high pressure applications.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSimplicity of Design\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e– Valves are easily maintained and serviced for long product life.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eOperates at minimum 15 GPM (57 LPM) at Pressures of 25–150 PSI (1,7-10,3 bar\u003c\/strong\u003e) – Ideal for pump-fed systems or high-flow city water systems.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eBuilt-in Atmospheric Vacuum Breaker\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e– Releases any vacuum created between the pump and the valve on shut down.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTwo Year Limited Warranty.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation Tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWe recommend the installation of an Atmospheric Vacuum Breaker between the pump and the valve.﻿\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cstrong\u003eManuals \u0026amp; Literature\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Brochure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"text-decoration: underline;\"\u003eInstruction Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e","brand":"K-Rain","offers":[{"title":"Default Title","offer_id":49369636667582,"sku":"aaa1792580744656","price":97.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/0968\/3134\/files\/k-rain---6404-rcw---6000-rcw-indexing-valve-4-outlet-4-zone-operation_1.png?v=1792580749","url":"https:\/\/gostyledaily.shop\/products\/k-rain-6404-rcw-6000-rcw-indexing-valve-4-outlet-4-zone-operation","provider":"My Store","version":"1.0","type":"link"}